E-Machine
SFX12V Power
Supply
SFX 12V Micro ATX
Switching Power Supply
FSP180-51NI(V) (
FSP180-51NIV ) with P4 Connector
SPI (Sparkle Power) FSP Group (Fortron Source)
PS-SFX-ES-180-51NIV
Down Load FSP180-51NI(V) ( FSP180-51NIV )
PDF Drawing
Features:
> High
efficiency
> Low ripple &Noise
> Output over voltage protection
> Short circuit protection on all output
> Reset table power shut down
> Approve by UL, CAS TUV, NEMKO CB
> Internal 12VDE fan
> 100% burn-in under high ambient temperature (50¢XC)
> Vacuum-impregnated transformer
> MTBF: 100K hours at 25¢XC
> 100% Hi-pot tested
> Line input fuse protection
Input Characteristics:
> Voltage:
115/230 VAC
> Frequency: 47Hz to 63Hz
> Inrush current: 50A cold, 70A warm at 132 VAC
> Input current: 6.0A maximum / 115V, 60Hz
3.0A maximum / 230V, 50Hz
Output Characteristics:
Output Minimum
Normal Maximum Load Line
Ripple
Voltage Load
Load Load Reg. Reg.
Noise
+3.3V 0.5A
8.3A 11.5/16.7A ±
5% ± 1% 50mV P-P
+5V
1.0A 6.3A 16/12.6A ± 5% ± 1%
50mV P-P
+12V
2.0A 2.0A 10A ± 5%
± 1% 120mV P-P
-12V
0.0A 0.15A 0.3A ± 10%
± 2% 120mV P-P
-5V
0.0A 0.1A
0.2A ± 10%
± 2% 120mV P-P
+5Vsb 0.0A
1.0 A 2.0A ± 5% ± 1% 50mV P-P
Specification:
> Remote
ON/OFF Control: The Power supply shall accept a logic open collector
level which will disable /enable all out put voltage (excluding +5V
standby).
> Temperature range: operating 0¢XC~50¢XC storage-20¢XC~+65¢XC
> Temperature coefficient:0.01%/¢XC
> Transient response: output voltage recovers in less than 1 ms max.
following a 25%load change
> Hold-up time: 16.6ms minimum - at 115V/60Hz.
16.6ms minimum - at 230V50Hz.
> Dielectric withstand: input / output 1800VAC for1 second, input to
frame ground 1800VAC for 1 second
> Humidity: 5~95% RH
> Efficiency: 65% min. 70% typical, at full load
> Power good signal: turn-on delay 100ms to 500ms
> Over voltage protection: +5V output 6.5V
+3.3V output 4.6V
+12V output 15.5V
 |