Enclosure Ratings (NEMA Standards)

Definitions Pertaining to Non-Hazardous Locations

  • Type 1 Enclosures are constructed for indoor use to provide a degree of protection to personnel against access to hazardous parts and to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt).
  • Type 2 Enclosures are constructed for indoor use to provide a degree of protection to personnel against access to hazardous parts, to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirty, and to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (dripping and light splashing).
  • Type 3 Enclosures are constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts, to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt) and windblown dusty, to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow), and that will be undamaged by the external formation of ice on the enclosure.
  • Type 3R Enclosures are constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts, to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt) to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow), and that will be undamaged by the external formation of ice on the enclosure.
  • Type 3S Enclosures are constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts, to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust) to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow), red for which the external mechanisms) remain operable when ice laden.
  • Type 3X Enclosures are constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts, to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt) and windblown dusty, to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow), that provides an additional level of protection against corrosion and that will be undamaged by the external formation of ice on the enclosure.
  • Type 3XR Enclosures are constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts, to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt), to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow), that will be undamaged by the external formation of ice on the enclosure that provides an additional level of protection against corrosion, and that will be undamaged by the external formation of ice on the enclosure.
  • Type 3SX Enclosures are constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts, to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dusty, to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snowy, that provides an additional level of protection against corrosion, and for which the external mechanisms) remain operable when ice laden.
  • Type 4 Enclosures are constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts, to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dusty, to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow, splashing water, and hose directed water), and that will be undamaged by the external formation of ice on the enclosure.
  • Type 4X Enclosures are constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts, to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (windblown dusty, to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow, splashing water, and hose directed water), that provides an additional level of protection against corrosion, and that will be undamaged by the external formation of ice on the enclosure.
  • Type 5 Enclosures are constructed for indoor use to provide a degree of protection to personnel against access to hazardous parts, to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and settling airborne dust, lint, fibers, and flyings), and to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (dripping and light splashing).
  • Type 6 Enclosures are constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts, to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt), to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (hose directed water and the entry of water during occasional temporary submersion at a limited depths), and that will be undamaged by the external formation of ice on the enclosure.
  • Type 6P Enclosures are constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts, to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt), to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (hose directed water and the entry of water during prolonged submersion at a limited depths), that provides an additional level of protection against corrosion and that will be undamaged by the external formation of ice on the enclosure.
  • Type 12 Enclosures are constructed (without knockouts) for indoor use to provide a degree of protection to personnel against access to hazardous parts, to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and circulating dust, lint, fibers, and flyings), and to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (dripping and light splashing).
  • Type 12K Enclosures are constructed (with knockouts) for indoor use to provide a degree of protection to personnel against access to hazardous parts, to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (failing dirt and circulating dust, lint, fibers, and flyings), and to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (dripping and light splashing).
  • Type 13 Enclosures are constructed for indoor use to provide a degree of protection to personnel against access to hazardous parts, to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and circulating dust, lint, fibers, and flyings), to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (dripping and light splashing), and to provide a degree of protection against the spraying, splashing, and seepage of oil and non-corrosive coolants.